HSE Projects with KT Impact

Project

Product type /

HSE responsible

Description

KT status

Remarks

EDMS reference (doc/presentation)

Actiwiz

Software /

H. Vincke & C. Theis

Assessment & comparison of the radiological hazard originating from materials used at CERN’s accelerators, optimize material selection

Academic licenses:

PSI, GSI, ESS, KEK, JLAB, Univ. of Michigan, Univ. of Upsala, ISIS, ELI
Commercial license: MedAustron, Integrated in KT portfolio (1) , distribution of version 3 under preparation with KT

EDMS 1256576, EDMS 1184236, Proceedings of the ICRS12 conference, (2012),

SATIF-12 conference proceedings

eSHIP-Nucleonica + RT7C

Software /

Y. Donjoux

e-Ship++ (electronic Shipment) is a software program for calculating radiological characteristics of packages for the shipment of radioactive material in accordance with ADR/IATA/IAEA transport regulations

Contract KT-019-120606 signed with Nucleonica GmbH. NDA-KC2929- DGS signed with Nucleonica

Under revision with KT Group (N. Ziogas) to create a new agreement

EDMS 1318819

UNAMED- Nucleonica

Software /

Y. Donjoux

Tool to calculate dose rate, LE, LA, CA, CS, Einh, Eing according to European and Swiss regulations

Project launched: KT group contacted (26.05.2014)

Project already partially included into e-SHIP, but to be separated

Currently under discussion – waiting feedback from NUCLEONICA

B-RAD radiation survey meter

Hardware /

M. Silari

Radiation survey meter operating in strong magnetic field for dose rate, contamination and gamma spectrometry measurements

Patent filed on 27 May 2014 (application number: EP14170108) KT fund granted early 2014 for preparing industrialisation. IP agreement with POLIMI (KM2395/KT/DGS/190A ), Licence agreement with ELSE Nuclear for industrialization (KR2785-KT-DGS-190L)

EDMS folder “B-Rad survey meter”

RPL reader

Hardware + Software /

H. Vincke

RPL dosimeter readout system. Using a combined method analysing RPL light emission (triggered by UV light) and light attenuation of blue light being sent through the dosimeter.

Patent being filed

The Japanese company Chiyoda Technol Corporation has expressed interest. KT is exploring more companies for commercialisation

RADSHIP

Software /

Y. Donjoux

Management of radioactive shipments, institutes, DGD generation

NTNU screening performed end of 2014

Web interface + data base

EDMS 1305687 RADSHIP KTT online. TechBrief completed and online + EDMS 1388098 / / NTNU Screening: EDMS 1424059

GESO (GEstion SOurces)

Software /

Y. Donjoux

Management of radioactive sources (control, loan, request, etc…)

According to Marco’s request, KT to be contacted

Web interface + data base – Not yet done

SPA6 cable

Hardware /

D. Perrin & M. Pangallo

Integrated cable with coaxial cables for ultralow current transportation and high voltage polarisation of radiation detectors (i.e. ionisation chambers)

No patent filed. Agreement between CERN store and DRAKA GmbH to benefit of special delivery conditions.

Cable produced by DRAKA GmbH and already used by several manufacturers of instrumentation for radiation protection (i.e. MIRION, SAPHYMO, BERTHOLD).

Special connectors developed with LEMO.

Report “CERN technology transfers to industry and society”, ISBN 92- 9083-240-1, 2005, CERN, p.39.

MARS CT

Hardware /

P. Carbonez

New CT scanner based on the Medipix detector

KT to be contacted

Project with the university of Christchurch in NZ

http://www.marsbioi maging.com/mars/

Kryolize

Software /

A. Henriques

Tool to size the minimum discharge area of a pressure relief Safety device, to protect cryogenic equipment from an accidental overpressure scenario

Commercial licence granted to Linde Kryotechnik (KR3496_KT_HSE_222L) and INFN (KR3628_KT_HSE_222L)

Academic licence granted to INFN-LNL (licence agreement KN2461/KT/DGS/222L), ESS (KN2462-KT-DGS- 222L), CEA (KN2548/KT/DGS/222L), KIT (KN2544-KT-DGS- 222L), GSI (KN2737/KT/DGS/222L) TRIUM (KN2758-KT- DGS-222L) and TU Dresden (KN2916-KT- DGS-222L). Registration of “Kryolize” trademark is filed in the EU. KT fund granted in March 2015.

Tool already being used at CERN by ~30 colleagues. Two other institutes showed interest in having a license (KIT and ITER).

Paper at the ICEC 2016 conference:

EDMS N. 1824767

Experimental results:

EDMS N. 1567987

EDMS N. 1769316

Software Development status Reports

EDMS 1534986

EDMS 1559984

RP Calibration laboratory

Facility /

P. Carbonez

New RP calibration laboratory, to be accredited as Secondary Standard Laboratory

Mentioned to KT as future SSL for performing instrument calibrations to external users

GEMPIX

Hardware /

F. Murtas & M. Silari

Radiation detector coupling a triple-GEM with Medipix readout

KT contacted

In contact with KT, Technology Brief prepared, contact ongoing with ARTEL (Arezzo, IT) for producing industrial version

NTNU Screening, EDMS 1460599

W-MON

Hardware + Software /

M. Silari, A. Curioni, D. Perrin, F. Murtas

Distributed system of radiation sensors for monitoring radioactivity in waste containers

CERN-AIST-Chiyoda collaboration agreement KE 2798/KT/DGS/232C for exploiting D-shuttle technology

CROMEHardware + Software /

H. Boukabache, D. Perrin

High reliability radiation monitors with CERN new readout electronics for measurement of pulsed radiation fields over a wide dynamic range. Complemented with high reliability alarm unit and uninterruptible power supply.KT contacted

Version for qualification under preparation and pre-series for the end of 2017.

Series production by CERN in 2018 and 2019.
UTOPIAHardware + Software /

E. Voulgari, D. Perrin
EPFL – Microsystèmes and Microélectronique

ASIC for the measurement of current over a wide dynamic range up to nine decades, starting from fA currentKT contactedPrototypes exist in two versions.
Radiation effects Consultancy / F. Szoncso Expert advice on non-standard radiation effects on watches and jewelleryConsultancy agreement with Chopard KR3747/KT/HSE/75

NOTES

(1) The KT group has a web-page showing their “portfolio”, a show-case of their projects with more detailed information (possible applications, advantages, limitations etc.) that could be of interest to potential partners:

http://knowledgetransfer.web.cern.ch/technology-transfer/external-partners/portfolio

Access to the PDF file